Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
Print this page Email this page Users Online: 1478
ORIGINAL ARTICLE
Year : 2022  |  Volume : 15  |  Issue : 6  |  Page : 857-861

Radiation exposure among anesthetist, orthopedic surgeon, and scrub nurse in orthopedic operation theater complex


1 Department of Anaesthesia, BJMC and SGH, Pune, Maharashtra, India
2 Department of Orthopaedics, BJMC and SGH, Pune, Maharashtra, India

Correspondence Address:
Dr. Yogesh Gavali
Department of Anaesthesia, BJMC and SGH, Pune, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/mjdrdypu.mjdrdypu_721_20

Rights and Permissions

Background and Aims: Orthopedic operation theater staff is exposed to primary and scattered radiation during various fluoroscopy-assisted operative procedures during their routine working hours. This exposure is associated with significant health hazard. This prospective study is designed primarily to determine the level of radiation exposure among them and to compare it with the current safety guidelines and secondarily to measure the cumulative scattered radiation exposure inside operation theater complex. Subjects and Methods: Total 15 thermoluminescent dosimeters (TLDs) were used during the study. Seven TLDs were used per team and per procedure at designated position. Participating staff were instructed to use personal protective equipment and to wear the TLDs at all times during their study period. TLDs were analyzed at the end of 6 months. Results: The mean value of radiation exposure of anesthesia machine, orthopedic surgeon, anesthetist with TLD above lead apron, anesthetist with TLD below lead apron, and scrub nurse was 0.05, 1.85, 0.1, 0, and 0.625 mSv units, respectively. The highest individual values for orthopedic surgeon, anesthetist with TLD above the lead apron, and scrub nurse were 2.75, 0.1, and 0.7 mSv units, respectively. All these readings were within permissible limit. Conclusions: If standard safety precautions were followed, cumulative ionizing radiation exposure to participating staff as well as scattered radiation exposure within operation theater complex is minimal and within permissible limit. Routine personal dosimetric monitoring is desirable in staff working with fluoroscopy-guided procedure along with the use of personal protective equipment. Periodic training on radiation risk and protection should be conducted for them to heighten the awareness.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1266    
    Printed53    
    Emailed0    
    PDF Downloaded78    
    Comments [Add]    

Recommend this journal